Reducing beam hardening effects and metal artefacts in spectral CT using Medipix3RX

dc.contributor.authorRajendran, K
dc.contributor.authorWalsh, MF
dc.contributor.authorde Ruiter, NJA
dc.contributor.authorChernoglazov, AI
dc.contributor.authorPanta, RK
dc.contributor.authorButler, APH
dc.contributor.authorButler, PH
dc.contributor.authorBell, ST
dc.contributor.authorAnderson, NG
dc.contributor.authorWoodfield, TBF
dc.contributor.authorTredinnick, SJ
dc.contributor.authorHealy, JL
dc.contributor.authorBateman, CJ
dc.contributor.authorAamir, R
dc.contributor.authorDoesburg, RMN
dc.contributor.authorRenaud, PF
dc.contributor.authorGieseg, SP
dc.contributor.authorSmithies, DJ
dc.contributor.authorMohr, JL
dc.contributor.authorMandalika, VBH
dc.contributor.authorOpie, AMT
dc.contributor.authorCook, NJ
dc.contributor.authorRonaldson, JP
dc.contributor.authorNik, SJ
dc.contributor.authorAtharifard, A
dc.contributor.authorClyne, M
dc.contributor.authorBones, PJ
dc.contributor.authorBartneck, C
dc.contributor.authorGrasset, R
dc.contributor.authorSchleich, N
dc.contributor.authorBillinghurst, M
dc.date.accessioned2018-04-27T02:37:07Z
dc.date.available2014-03-26
dc.date.issued2014-03
dc.date.submitted2014-02-11
dc.description.abstractThis paper discusses methods for reducing beam hardening effects and metal artefacts using spectral x-ray information in biomaterial samples. A small-animal spectral scanner was operated in the 15 to 80 keV x-ray energy range for this study. We use the photon-processing features of a CdTe-Medipix3RX ASIC in charge summing mode to reduce beam hardening and associated artefacts. We present spectral data collected for metal alloy samples, its analysis using algebraic 3D reconstruction software and volume visualisation using a custom volume rendering software. The cupping effect and streak artefacts are quantified in the spectral datasets. The results show reduction in beam hardening effects and metal artefacts in the narrow high energy range acquired using the spectroscopic detector. A post reconstruction comparison between CdTe-Medipix3RX and Si-Medipix3.1 is discussed. The raw data and processed data are made available (http://hdl.handle.net/10092/8851) for testing with other software routines.
dc.format.extent13 pages
dc.identifierhttps://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=elements_prod&SrcAuth=WosAPI&KeyUT=WOS:000336123200075&DestLinkType=FullRecord&DestApp=WOS_CPL
dc.identifier.citationRajendran et al. (2014). Reducing beam hardening effects and metal artefacts in spectral CT using Medipix3RX. Journal of Instrumentation, 9, P03015-P03015. doi:10.1088/1748-0221/9/03/P03015
dc.identifier.doi10.1088/1748-0221/9/03/P03015
dc.identifier.eissn1748-0221
dc.identifier.issn1748-0221
dc.identifier.otherAH4UE (isidoc)
dc.identifier.urihttps://hdl.handle.net/10182/9284
dc.language.isoen
dc.publisherIOP Publishing for Sissa Medialab
dc.relationThe original publication is available from IOP Publishing for Sissa Medialab - https://doi.org/10.1088/1748-0221/9/03/P03015 - https://doi.org/10.1088/1748-0221/9/03/p03015
dc.relation.isPartOfJournal of Instrumentation
dc.relation.ispartofJournal of Instrumentation
dc.relation.urihttps://doi.org/10.1088/1748-0221/9/03/P03015
dc.rights© CERN 2014, published under the terms of the Creative Commons Attribution 3.0 License by IOP Publishing Ltd and Sissa Medialab srl. Any further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation and DOI.
dc.rights.ccnameAttribution
dc.rights.ccurihttps://creativecommons.org/licenses/by/4.0/
dc.subjectmedical-image reconstruction methods and algorithms
dc.subjectcomputer-aided diagnosis
dc.subjectX-ray detectors
dc.subjectcomputerized tomography (CT)
dc.subjectcomputed Radiography (CR)
dc.subject.anzsrcANZSRC::020203 Particle Physics
dc.subject.anzsrcANZSRC::11 Medical and Health Sciences
dc.subject.anzsrc2020ANZSRC::40 Engineering
dc.subject.anzsrc2020ANZSRC::51 Physical sciences
dc.titleReducing beam hardening effects and metal artefacts in spectral CT using Medipix3RX
dc.typeJournal Article
dspace.entity.typePublication
lu.contributor.unitLincoln University
lu.contributor.unitLincoln Agritech
lu.identifier.orcid0000-0002-7512-5583
pubs.issue3
pubs.notesArticle number P03015
pubs.publication-statusPublished
pubs.publisher-urlhttps://doi.org/10.1088/1748-0221/9/03/p03015
pubs.volume9
Files